ClarityChrom Prep 7.2

Product No:

A1685-11

single instrument license one time base

SKU: A1685-11 Category: Tags: ,

Single instrument license, one time base

ClarityChromPrep is an easy-to-use Chromatography Data System for workstations. It includes the full functionality of our ClarityChrom workstation, but also includes the KNAUER fraction collector control and fractionation option. The optional extensions for GC control, PDA, SST, GPC and MS allow to use the software for a wide spectrum of application. All KNAUER devices with a control interface can be controlled. Additionally, devices and systems from more than 45 manufacturers are supported.

The ClarityChromPrep also includes the drivers of several fraction collectors and supports the peak recognition by level and/or slope as well as fractionation by time. In the fraction collector configuration the delay and the fraction vial volume can be defined. This ensures that the target substance will be collected in the fraction vial and the fraction vial will not overflow. If a chromatogram of your separation already exists, the required fractionation commands can be derived directly from the chromatogram with a double mouse-click. The rack view gives an overview of the already collected fraction and their volume. It also includes links to the matching chromatograms of the fractions; with a double mouse-click the chromatogram can be opened. The manual fraction control, the option to use the KNAUER electric valves for fractionation and mass-triggered fractionation with the supported QUAD-MS gives you more flexibility. The combination of virtual detector and virtual fraction collector allows for optimizing the fractionation settings from an existing chromatogram of your separations without any physically existing device and, therefore, without the loss of solvent or target substance.

This license allows for control of one system.

Technical Data

Software

Software name ClarityChromPrep
Extensions / Licenses Fraction collection, Mass spectrometry, System suitability, PDA / 3D UV, SEC/GPC
System architecture 32-bit CDS
Operating system Windows 10, Windows 7, Windows 8/8.1, Windows Vista SP2, all 32- and 64-bit; Windows XP SP3 (32-bit only)

Expandability

Stand-alone Workstation version, max. 4 systems controlled by one computer, max. 3 complete systems, max. 2 systems with PDA detector
Client/server No Client/Server functionality
Multi-user environment Selectable system of user accounts with independently customizable behavior and appearance for individual users
Network environment Easy offline data sharing (at the file level) among all stations in a local network
Fields of application Analytical HPLC, GPC/SEC, GC, MS
Supported instruments All Knauer devices are supported, driver for devices from many other manufacturers are available
Instrument connection Supports RS-232, Ethernet, PCI interface card, A/D-D/A interface
Recommended PC hardware Pentium 2 GHz, 2 GB RAM, 10 GB free hard disk space, separate graphics card if one PC should control more than one system, 4 GB RAM recommended for PDA detectors
Graphics capabilities Multiple chromatogram view and overlay, PDA view
Integration 27 integration parameters (peak width, threshold, tangent slope ratio etc.) integration parameters programmable in time, automatic re-integration
Calculation types with/without calibration (int./ext. standard method)
Security and GLP Installation qualification test of the software; FDA 21 CFR Part 11 conformance, validation with virtual detector
Instrument control method-based instrument control, Instrument status display and Direct-Control mode,
Calibration 6 types of calibration curves, up to 20 levels, reference peaks, groups, unlimited number of standards (peaks), LOD, LOQ
Chromatogram operations Overlay view, custom labels and settings, also applying mathematical operations to chromatograms
Automation Sequences, automatic launch of selected commands or applications immediately following chromatogram acquisition – Post run, Batch
Presentation of results Integrated customizable table of results, columns with userdefined calculation, summary table, and export in text or database format
Calculations Custom: 12 predefined mathematical operators, 15 basic and 4 summary functions, special: Kovats indexes for GC, determination of noise/drift, performance calculations
Data import and export ASCII, AIA, dBase

Additional options/extensions

FRC option for preparative HPLC, adds tools for detector controlled and mass-triggered fraction collection, solvent recycling
FRC features Fractionation can be controlled by time (volume), level, slope including AND/OR combination of these criteria, manual control of fractionation during a run
PDA option separate license option; 3D chromatogram, peak purity analysis, spectrum search in self-made or commercial spectra library
GPC/SEC option separate license option; molecular weight determination in size exclusion chromatography with various calibration methods
System suitability test separate license option; automates the calculation of system suitability parameters for system validation

Downloads and more information