Autosampler AS 6.1L

Product No:

AAA40AA

preparative HPLC autosampler

SKU: AAA40AA Category:

preparative version

The Autosampler AS 6.1L can inject from up to 768 positions when equipped with microtiter plates (either high or low formats) or from up to 108 standard 2 ml sample vials. Sample carryover is significantly minimized thanks to a highly-effective interior and exterior needle wash procedure. This autosampler is also fast and flexible: one complete sample injection cycle takes less than one minute, including needle wash. Three different injection modes are supported; “full loop filling” (highest precision and reproducibility), “partial loop filling” (variable volumes, e.g. for dilution series) and “µl pickup” (loss-free injection of extremely small sample volumes), allowing the user to optimize sample usage. The headspace pressure function prevents bubbles from forming in the vial during sample uptake. Precolumn derivatization is supported. Preparative version for sample volumes up to 10 ml.

Technical Data

Sample injection

Autosampler Flow Path Preparative
Maximum back pressure 200 bar
Vial/plate dimensions max. plate/vial height: 47 mm (incl. septa or capmat)
Injection volume range 0.1 µl – 10 ml depending on sample loop
Sample loop 10 ml
Dispenser syringe 2500 µl
Headspace pressure built-in compressor, only for sample vials with septum
Switching time inj. valve < 100 ms
Piercing needle precision ± 0.6 mm
Sample tray cooling none
Vial detection missing vial/well plate detection by sensor
Needle wash programmable: wash between injections and wash between vials
Wetted materials Tefzel® (ETFE), Glass, Teflon® (PTFE), Kel-F® (PCTFE), stainless steel, PEEK

Analytical performance

Injection modes partial loop filling
Injection precision RSD (Relative Standard Deviation):full loop injection: <0.3%partial loop injection at injection volume>5 µl: <0.5%microliter pickup injection at an injection volume>5 µl: <1.0%
Sample carryover < 0.1 % with standard needle washRSD ≤ 1.0 % for partial loop filling, injection volumes> 10 µl up to 50 % of the installed sample loop
Injections per vial max. 9 injections
Injection cycle time minimum 7 s from the same vial, 14 s from different vials;< 60 s for>100 µl sample injection in all injection modes, incl. 300 µl needle wash
Analysis time max. 9 h, 59 min, 59 s

Communication

Inputs 2 programmable TTL inputs (next injection, freeze, stop)
Outputs 1 programmable relay output (inject marker, auxiliary, alarm)
Control Ethernet (LAN)
Interfaces LAN, analog

Technical parameters

Ambient conditions temperature range: 10–40 °C; 50–104 °F air humidity: 20 – 80%

General

Power supply 95–240 V AC
Dimensions 377 x 300 x 510 mm (W x H x D)
Weight 30 kg

Downloads and more information

  • AZURA Autosampler AS 6.1L User Manual EN (V6821)

    • Manual
    • English
    • PDF
    • 2.7 MB
  • AZURA Autosampler AS 6.1L Benutzerhandbuch DE (V6821)

    • Manual
    • German
    • PDF
    • 2.8 MB
  • List of supported devices in chromatography data systems EN (V1663)

    Device support in KNAUER CDS / KNAUER device support in 3rd party software

    • information
    • English
    • PDF
    • 328.1 KB