Single instrument license, one time base
ClarityChromPrep is an easy-to-use Chromatography Data System for workstations. It includes the full functionality of our ClarityChrom workstation, but also includes the KNAUER fraction collector control and fractionation option. The optional extensions for GC control, PDA, SST, GPC and MS allow to use the software for a wide spectrum of application. All KNAUER devices with a control interface can be controlled. Additionally, devices and systems from more than 45 manufacturers are supported.
The ClarityChromPrep also includes the drivers of several fraction collectors and supports the peak recognition by level and/or slope as well as fractionation by time. In the fraction collector configuration the delay and the fraction vial volume can be defined. This ensures that the target substance will be collected in the fraction vial and the fraction vial will not overflow. If a chromatogram of your separation already exists, the required fractionation commands can be derived directly from the chromatogram with a double mouse-click. The rack view gives an overview of the already collected fraction and their volume. It also includes links to the matching chromatograms of the fractions; with a double mouse-click the chromatogram can be opened. The manual fraction control, the option to use the KNAUER electric valves for fractionation and mass-triggered fractionation with the supported QUAD-MS gives you more flexibility. The combination of virtual detector and virtual fraction collector allows for optimizing the fractionation settings from an existing chromatogram of your separations without any physically existing device and, therefore, without the loss of solvent or target substance.
This license allows for control of one system.
Technical Data
Software
Software name | ClarityChromPrep |
---|---|
Extensions / Licenses | Fraction collection, Mass spectrometry, System suitability, PDA / 3D UV, SEC/GPC |
System architecture | 32-bit CDS |
Operating system | Windows 10, Windows 7, Windows 8/8.1, Windows Vista SP2, all 32- and 64-bit; Windows XP SP3 (32-bit only) |
Expandability
Stand-alone | Workstation version, max. 4 systems controlled by one computer, max. 3 complete systems, max. 2 systems with PDA detector |
---|---|
Client/server | No Client/Server functionality |
Multi-user environment | Selectable system of user accounts with independently customizable behavior and appearance for individual users |
Network environment | Easy offline data sharing (at the file level) among all stations in a local network |
Fields of application | Analytical HPLC, GPC/SEC, GC, MS |
Supported instruments | All Knauer devices are supported, driver for devices from many other manufacturers are available |
Instrument connection | Supports RS-232, Ethernet, PCI interface card, A/D-D/A interface |
Recommended PC hardware | Pentium 2 GHz, 2 GB RAM, 10 GB free hard disk space, separate graphics card if one PC should control more than one system, 4 GB RAM recommended for PDA detectors |
Graphics capabilities | Multiple chromatogram view and overlay, PDA view |
Integration | 27 integration parameters (peak width, threshold, tangent slope ratio etc.) integration parameters programmable in time, automatic re-integration |
Calculation types | with/without calibration (int./ext. standard method) |
Security and GLP | Installation qualification test of the software; FDA 21 CFR Part 11 conformance, validation with virtual detector |
Instrument control | method-based instrument control, Instrument status display and Direct-Control mode, |
Calibration | 6 types of calibration curves, up to 20 levels, reference peaks, groups, unlimited number of standards (peaks), LOD, LOQ |
Chromatogram operations | Overlay view, custom labels and settings, also applying mathematical operations to chromatograms |
Automation | Sequences, automatic launch of selected commands or applications immediately following chromatogram acquisition – Post run, Batch |
Presentation of results | Integrated customizable table of results, columns with userdefined calculation, summary table, and export in text or database format |
Calculations | Custom: 12 predefined mathematical operators, 15 basic and 4 summary functions, special: Kovats indexes for GC, determination of noise/drift, performance calculations |
Data import and export | ASCII, AIA, dBase |
Additional options/extensions
FRC option | for preparative HPLC, adds tools for detector controlled and mass-triggered fraction collection, solvent recycling |
---|---|
FRC features | Fractionation can be controlled by time (volume), level, slope including AND/OR combination of these criteria, manual control of fractionation during a run |
PDA option | separate license option; 3D chromatogram, peak purity analysis, spectrum search in self-made or commercial spectra library |
GPC/SEC option | separate license option; molecular weight determination in size exclusion chromatography with various calibration methods |
System suitability test | separate license option; automates the calculation of system suitability parameters for system validation |